BSD Instruments — Authorized Distributor in Türkiye

Polus Engineering is the authorized distributor for BSD Instruments in Türkiye — offering a comprehensive range of surface characterization and sorption analysis equipment. Click any instrument to learn more.

BSD-660 Series

Advanced Specific Surface Area and Micropore Analyzer

The BSD-660 is a fully automatic, high-throughput physisorption analyzer for specific surface area, pore volume and meso-, micro- and ultra-micropore size distribution (0.35–500 nm), with surface areas measurable from 0.0005 m²/g. Two independent A/B stations provide up to 12 analysis ports, each able to run a different gas and temperature. Degassing and adsorption testing take place in situ in the same position, so the sample cell never has to be removed. Also measures adsorption isotherms of N₂, Ar, Kr, CO₂ and combustible gases such as H₂ and CH₄, with optional corrosive-gas (MC) and vapor (MV) versions.

📄 Download Datasheet

BSD-VVS & DVS Series

Multi-station Gravimetric Gas /Vapor Sorption Analyzer

The VVS and DVS series measure gas and vapor adsorption isotherms gravimetrically on 4 or 8 stations in the same test environment, using a high-resolution microbalance (down to 0.1 µg). The BSD-VVS uses the vacuum static method (P/P₀ 0.1–98%), the BSD-DVS uses the dynamic gas-flow method (RH 2–98%) and also handles corrosive gases and vapors, and the combined VVS&DVS offers both in one instrument. It also supports equal-pressure adsorption kinetics and auto-cycle adsorption performance testing, with test temperatures from −5 °C to 150 °C (±0.1 °C).

📄 Download Datasheet

BSD-PH Series

High Pressure Gas Sorption Analyzer

The BSD-PH series measures high-pressure gas adsorption isotherms, PCT curves, adsorption kinetics and heats of adsorption for hydrogen storage, shale gas, coal-bed methane and gas separation research. The standard BSD-PH covers vacuum to 20 MPa with 1, 2 or 4 test ports, and the BSD-PHU extends this to 50 or 69 MPa. Test temperatures range from −196 °C to 900 °C, including 77 K hydrogen adsorption. Other models add equal-pressure kinetics and TPD (PHE), atmospheric desorption rate (PHEM), stress-loaded rock and coal cores (PHC), and multi-component competitive adsorption (PHM).

📄 Download Datasheet

BSD-MAB

Multi-component Adsorption Breakthrough Curve Analyzer

The BSD-MAB measures gas and vapor adsorption breakthrough curves under real process conditions, with adjustable adsorbent, bed layers, temperature, pressure, concentration and flow rate. Two-component breakthrough is analyzed with the built-in thermal conductivity detector, and multi-component competitive adsorption and displacement desorption with an optional chromatograph or mass spectrometer. Applications include gas separation, PSA/TSA and hydrogen purification studies, adsorbent regeneration and cycling, ppm-level pollutant adsorption (TVOC, SO₂, NH₃), and gas-separation membrane characterization.

📄 Download Datasheet

BSD-C200

Automatic Chemisorption Analyzer

The BSD-C200 is an automatic chemisorption analyzer for catalyst characterization, performing TPD, TPR, TPO, TPSR, TPS and pulse titration. It also determines desorption kinetics (activation energy, pre-exponential factor and desorption order). Two automatically switching furnaces (room temperature to 1200 °C, 1–100 °C/min) allow auto-cycle catalyst lifetime evaluation without manual cooling. The analyzer has 12 gas inlets, 3 MFCs for mixed gases, a steam generator, and test pressures up to 1/3/10 MPa. Signals are detected by TCD, with optional mass spectrometry or FT-IR.

📄 Download Datasheet

BSD-BET400

Auto Fast Specific Surface Area Analyzer

The BSD-BET400 is a fully automated analyzer for fast BET surface area testing of samples with small to medium surface areas, using the dynamic chromatography method. Four in-situ degassing and analysis stations test 4 samples in about ten minutes, measuring surface areas from 0.01 m²/g with ±1% relative error. A thermostatted internal reference removes the need for standard reference samples. Combined with stable operation and a gas-purification cold trap, this makes it well suited to industrial quality control of battery materials, metal powders and other powders, granules and fibers.

📄 Download Datasheet

BSD-PB

Comprehensive Membrane Pore Size Analyzer

The BSD-PB characterizes the through-pores of filter and separation membranes. It measures bubble point; maximum, minimum, mean and most-probable pore size; and pore size distribution. It also determines gas and liquid permeability and flux, flow–pressure curves, integrity and hollow-fiber burst pressure. The BSD-PB covers 0.012–200 µm, the BSD-PBB 0.12–200 µm and the BSD-PBL 5–50 nm. It handles flat membranes (battery separators, carbon paper, nonwovens, filter paper, ceramic and sintered-metal membranes) as well as hollow-fiber and tubular membranes.

📄 Download Datasheet

BSD-VD12

Vacuum Degassing Station

The BSD-VD12 is a vacuum degassing station that prepares samples for surface area and high-pressure sorption analysis on the BSD-660 and BSD-PH series. Two independent stations provide 12 ports (6 per station) for simultaneous degassing, heated up to 400 °C (±0.1 °C) with a 32-segment programmable touch-screen controller. Pressure-controlled pumping prevents sample loss, a pressure sensor detects when degassing is complete, and degas curves are logged. An optional cold trap protects sensitive samples such as MOFs and COFs, as well as the vacuum system.

📄 Download Datasheet

BSD-TD

Automatic True Density & Porosity Analyzer

The BSD-TD measures the true (skeletal) density and the open and closed porosity of powders, granules, blocks, foams, slurries and non-volatile liquids by gas displacement. It is accurate to ±0.03%, with ±0.015% repeatability and 0.0001 g/ml resolution. Each station completes a test in 0.5–1 minute, and one or two analysis stations are available. The bottom-loading sample cell (1–25 ml, with customized and square-cell options) acts directly as the test chamber, reducing dead volume. A programmed thermostatic chamber (better than 0.1 °C) and pre-conditioned gas keep measurements stable.

For the full BSD Instruments range, contact info@poluseng.com